DC/DC Converter
TMDC 06H Series, 6 Watt
•
Fully encapsulated chassis mount
modules
•
High 2:1 input voltage range: 80-160
VDC
•
•
Reinforced I/O-isolation 3’000 VAC
•
Operating temperature range -40 to
+80°C without derating
•
Protection against overload,
undervoltage and short circuit
•
DC-OK (LED) and Remote On/Off
function
•
•
IEC/EN/UL 62368-1 safety approvals
Harsh industrial EMC capabilities:
Integrated filters for emission (EN
55032) & immunity (EN 55035)
3-year product warranty
UL 62368-1 IEC 62368-1
The TMDC 06H series complements Traco Power’s successful TMDC line of Industrial DC/DC off-board modules. All models provide a high 2:1 input voltage
range from 80-160 VDC and a reinforced 3000 VAC isolation voltage as well as
fully regulated outputs. Internal filters limit conducted and radiated emissions
(EN 55032 class A) but also increase the modules EMC immunity (EN 55035).
The modules come in fully encapsulated plastic packages and feature a high
temperature range from –40° up to 80°C without derating. Latest IT safety certifications (UL 62368-1) and DC-OK and remote on/off functions complete the
package to provide an ideal solution for many harsh industrial and 110 VDC
battery applications in need of a reinforced isolation to provide a safe SELV output.
Models
Order Code
Input Voltage
TMDC 06-7211H
TMDC 06-7212H
TMDC 06-7213H
TMDC 06-7215H
TMDC 06-7218H
TMDC 06-7222H
TMDC 06-7223H
TMDC 06-7225H
Output 1
Output 2
Range
Vnom
Imax
80 - 160 VDC
(110 VDC nom.)
5.1 VDC
12 VDC
15 VDC
24 VDC
48 VDC
+12 VDC
+15 VDC
+24 VDC
1'200 mA
500 mA
400 mA
250 mA
125 mA
250 mA
200 mA
125 mA
Vnom
–12 VDC
–15 VDC
–24 VDC
Efficiency
Imax
typ.
250 mA
200 mA
125 mA
79 %
83 %
83 %
84 %
82 %
84 %
84 %
83 %
Options
TMDC-MK1
- Optional DIN-Rail Mounting Kit: www.tracopower.com/products/tmdc-mk1.pdf
www.tracopower.com
November 30, 2022
Page 1 / 4
TMDC 06H Series, 6 Watt
Input Specifications
Input Current
8 mA typ.
66 mA typ.
170 VDC max. (1 s max.)
69 VDC min. / 74 VDC typ.
1'250 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
- At no load
- At full load
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Voltage Balance
(symmetrical load)
- Cross Regulation
(25% / 100% asym. load)
- single output
- dual output
Capacitive Load
- single output
- dual output
±2% max.
0.5% max.
0.5% max.
0.5% max.
0.5% max. (Output 1)
0.5% max. (Output 2)
dual output models: 2% max.
single output models:
dual output models:
single output models:
dual output models:
dual output models: 5% max.
5.1 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
48 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
24 / -24 Vout models:
5.1 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
48 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
24 / -24 Vout models:
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Transient Response
- Response Deviation
- Response Time
75 mVp-p typ.
75 mVp-p typ.
75 mVp-p typ.
180 mVp-p typ.
180 mVp-p typ.
75 / 75 mVp-p typ.
75 / 75 mVp-p typ.
180 / 180 mVp-p typ.
680 µF max.
330 µF max.
330 µF max.
150 µF max.
68 µF max.
150 / 150 µF max.
150 / 150 µF max.
68 / 68 µF max.
Not required
±0.02 %/K max.
30 ms typ. / 60 ms max.
Continuous, Automatic recovery
120 - 180% of Iout max.
150% typ. of Iout max.
5% max. (75% to 100% Load Step)
500 µs max. (75% to 100% Load Step)
Safety Specifications
Safety Standards
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
EN 62368-1
IEC 62368-1
UL 62368-1
www.tracopower.com/overview/tmdc06h
PD 3
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 30, 2022
Page 2 / 4
TMDC 06H Series, 6 Watt
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EMS Immunity
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
- Conducted RF Disturbances
- PF Magnetic Field
EN 55032 class A (internal filter)
FCC Part 15 class A (internal filter)
EN 55032 class A (internal filter)
FCC Part 15 class A (internal filter)
EN 55035 (Multimedia)
Air: EN 61000-4-2, ±8 kV, perf. criteria A
Contact: EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
EN 61000-4-6, 10 Vrms, perf. criteria A
Continuous: EN 61000-4-8, 100 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Cooling System
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Working Voltage (rated)
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Housing Material
Potting Material
Housing Type
Mounting Type
Connection Type
Weight
- Input to Output, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
Environmental Compliance - REACH Declaration
- RoHS Declaration
95% max. (non condensing)
–40°C to +93°C
+105°C max.
–50°C to +125°C
4 %/K above 80°C
See application note: www.tracopower.com/overview/tmdc06h
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
2.5 mA typ.
-0.5 to 0.5 mA
5'000 m max.
220 - 280 kHz (PWM)
250 kHz typ. (PWM)
Reinforced Insulation
1'000 VAC
3'000 VAC
1'000 MΩ min.
2'200 pF typ.
4'163'000 h (MIL-HDBK-217F, ground benign)
Plastic resin (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Plastic Case
Chassis Mount
Screw Terminal
48 g
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 6c, 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).
The SCIP number is provided on request.)
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tmdc06h
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 30, 2022
Page 3 / 4
TMDC 06H Series, 6 Watt
Outline Dimensions
4x Ø2.3
Pinout
3
2
1
(1.02)
Top view
26.0
6
5
4
(1.34)
34.0
Pin*
DC ON
Power good LED
Single Output
Dual Output
1
Remote
Remote
2
–Vin (GND)
–Vin (GND)
3
+Vin (Vcc)
+Vin (Vcc)
4
–Vout
–Vout
5
NC
Common
6
+Vout
+Vout
NC: No Connection
44.0
* Wires 1.5 mm2 max.
(1.73)
53.0
33.0
10.0
(1.30)
(0.39)
(1.33)
3.5
33.8
(0.44)
(0.14)
11.3
(1.04)
26.5
(2.09)
Dimensions in mm (inch)
Tolerances: x.x ±0.5 (±0.02)
x.xx ±0.25 (±0.01)
© Copyright 2022 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. November 30, 2022
Page 4 / 4
很抱歉,暂时无法提供与“TMDC 06-7225H”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+468.905381+56.03122
- 10+360.5547310+43.08401